CVE-2017-20216 FLIR Thermal Camera PT-Series firmware version 8.0.0.64 Unauthenticated Remote Command Injection
설명
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
영향 받는 제품 제품 1개
-
FLIR Systems, Inc.
FLIR Thermal Camera PT-Series
영향 받는 버전
- 8.0.0.64
해결 버전
해결된 버전 정보가 없습니다.
참고 자료 5건
- cxsecurity.com https://cxsecurity.com/issue/WLB-2017090203 (새 창)
- packetstormsecurity.com https://packetstormsecurity.com/files/144321 (새 창)
- web.archive.org https://web.archive.org/web/20171011125811/https://www.flir.com/security/blog/details/?ID=87043 (새 창)
- exploit-db.com https://www.exploit-db.com/exploits/42785/ (새 창)
- zeroscience.mk https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5438.php (새 창)