CVE-2020-28391 A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Al…
설명
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
영향 받는 제품 제품 11개
-
Siemens
SCALANCE X-200 switch family (incl. SIPLUS NET variants)
영향 받는 버전
- 버전 정보 확인 필요
해결 버전
해결된 버전 정보가 없습니다.
-
Siemens
SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
영향 받는 버전
- 버전 정보 확인 필요
해결 버전
해결된 버전 정보가 없습니다.
-
Siemens
SCALANCE X-200RNA switch family
영향 받는 버전
- 버전 정보 확인 필요
해결 버전
해결된 버전 정보가 없습니다.
-
NVD 기준 해결 버전 있음
siemens
scalance x200-4pirt firmware
영향 받는 버전
- 5.5.0 미만
해결 버전
- 5.5.0 이상
-
NVD 기준 해결 버전 있음
siemens
scalance x201-3pirt firmware
영향 받는 버전
- 5.5.0 미만
해결 버전
- 5.5.0 이상
-
NVD 기준 해결 버전 있음
siemens
scalance x202-2irt firmware
영향 받는 버전
- 5.5.0 미만
해결 버전
- 5.5.0 이상
-
NVD 기준 해결 버전 있음
siemens
scalance x202-2pirt firmware
영향 받는 버전
- 5.5.0 미만
해결 버전
- 5.5.0 이상
-
NVD 기준 해결 버전 있음
siemens
scalance x202-2pirt siplus net firmware
영향 받는 버전
- 5.5.0 미만
해결 버전
- 5.5.0 이상
-
NVD 기준 해결 버전 있음
siemens
scalance x204irt firmware
영향 받는 버전
- 5.5.0 미만
해결 버전
- 5.5.0 이상
-
NVD 기준 해결 버전 있음
siemens
scalance xb205-3 firmware
영향 받는 버전
- 5.2.5 미만
해결 버전
- 5.2.5 이상
-
NVD 기준 해결 버전 있음
siemens
scalance xb205-3ld firmware
영향 받는 버전
- 5.2.5 미만
해결 버전
- 5.2.5 이상