CVE-2022-32252 A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The appl…
설명
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker.
영향 받는 제품 제품 1개
-
해결 버전 있음
Siemens
SINEMA Remote Connect Server
영향 받는 버전
- V3.1 미만
해결 버전
- V3.1 이상