CVE-2024-39872 A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The…
설명
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the 'Manage firmware updates' role to escalate their privileges on the underlying OS level.
영향 받는 제품 제품 1개
-
해결 버전 있음
Siemens
SINEMA Remote Connect Server
영향 받는 버전
- V3.2 SP1 미만
해결 버전
- V3.2 SP1 이상