kcve.ai취약점 정보 · 내 자산 확인

CVE-2024-47508 Junos OS Evolved: Specific low privileged CLI commands and SNMP GET requests can trigger a resource leak #2

설명

An Allocation of Resources Without Limits or Throttling vulnerability in the PFE management daemon (evo-pfemand) of Juniper Networks Junos OS Evolved allows an authenticated, network-based attacker to cause an FPC crash leading to a Denial of Service (DoS).When specific SNMP GET operations or specific low-priviledged CLI commands are executed, a GUID resource leak will occur, eventually leading to exhaustion and resulting in FPCs to hang. Affected FPCs need to be manually restarted to recover. GUID exhaustion will trigger a syslog message like one of the following: evo-pfemand[<pid>]: get_next_guid: Ran out of Guid Space ... evo-aftmand-zx[<pid>]: get_next_guid: Ran out of Guid Space ... The leak can be monitored by running the following command and taking note of the values in the rightmost column labeled Guids: user@host> show platform application-info allocations app evo-pfemand/evo-pfemand In case one or more of these values are constantly increasing the leak is happening. This issue affects Junos OS Evolved: * All versions before 21.2R3-S8-EVO, * 21.3 versions before 21.3R3-EVO; * 21.4 versions before 22.1R2-EVO, * 22.1 versions before 22.1R1-S1-EVO, 22.1R2-EVO. Please note that this issue is similar to, but different from CVE-2024-47505 and CVE-2024-47509.

영향 받는 제품 제품 1개

  • Juniper Networks

    Junos OS Evolved

    해결 버전 있음

    영향 받는 버전

    • 21.2 이상 21.2R3-S8-EVO 미만
    • 21.3 이상 21.3R3-EVO 미만
    • 21.4 이상 21.4R2-EVO 미만
    • 버전 정보 확인 필요

    해결 버전

    • 21.2R3-S8-EVO 이상
    • 21.3R3-EVO 이상
    • 21.4R2-EVO 이상

참고 자료 1건

‹ 목록

점검 지원 범위 문의

도입 문의