kcve.ai취약점 정보 · 내 자산 확인

CVE-2025-71200 mmc: sdhci-of-dwcmshc: Prevent illegal clock reduction in HS200/HS400 mode

설명

In the Linux kernel, the following vulnerability has been resolved: mmc: sdhci-of-dwcmshc: Prevent illegal clock reduction in HS200/HS400 mode When operating in HS200 or HS400 timing modes, reducing the clock frequency below 52MHz will lead to link broken as the Rockchip DWC MSHC controller requires maintaining a minimum clock of 52MHz in these modes. Add a check to prevent illegal clock reduction through debugfs: root@debian:/# echo 50000000 > /sys/kernel/debug/mmc0/clock root@debian:/# [ 30.090146] mmc0: running CQE recovery mmc0: cqhci: Failed to halt mmc0: cqhci: spurious TCN for tag 0 WARNING: drivers/mmc/host/cqhci-core.c:797 at cqhci_irq+0x254/0x818, CPU#1: kworker/1:0H/24 Modules linked in: CPU: 1 UID: 0 PID: 24 Comm: kworker/1:0H Not tainted 6.19.0-rc1-00001-g09db0998649d-dirty #204 PREEMPT Hardware name: Rockchip RK3588 EVB1 V10 Board (DT) Workqueue: kblockd blk_mq_run_work_fn pstate: 604000c9 (nZCv daIF +PAN -UAO -TCO -DIT -SSBS BTYPE=--) pc : cqhci_irq+0x254/0x818 lr : cqhci_irq+0x254/0x818 ...

영향 받는 제품 제품 1개

  • Linux

    Linux

    해결 버전 있음

    영향 받는 버전

    • 6.0

    해결 버전

    • 6.0 미만
    • 6.1.162 이상
    • 6.6.122 이상
    • 6.12.68 이상
    • 6.18.8 이상

참고 자료 5건

‹ 목록

점검 지원 범위 문의

도입 문의