CVE-2026-100659 Netty 4.2.0 through 4.2.17 HTTP/3 Request Routing Bypass
설명
Netty's HTTP/3 codec (io.netty:netty-codec-http3) in versions 4.2.0.Final through 4.2.17.Final does not enforce the RFC 9114 requirement that the :authority pseudo-header field and a literal host header field, when both present, carry the same value. A remote unauthenticated peer can send a single HEADERS frame containing both fields with differing, attacker-controlled values; the request is accepted and delivered to the application with two conflicting authorities, allowing routing, virtual-host, and access-control decisions to be bypassed when different components in the request path consult different fields. This issue is fixed in 4.2.18.Final.
영향 받는 제품 제품 1개
-
해결 버전 있음
netty
netty
영향 받는 버전
- 4.2.0.Final 이상 4.2.18.Final 미만
해결 버전
- 4.2.18.Final 이상
- 4.2.18.Final