CVE-2026-22105 Use of default password based on serial number
설명
Delta UFC500 charging stations derive the default credentials of the Service account from character positions of the device serial number. An unauthenticated attacker with adjacent network access can reconstruct the resulting password, or exhaust the keyspace, and log in to read and change sensitive settings such as the OCPP backend.
영향 받는 제품 제품 1개
-
해결 버전 있음
Delta Electronics
Delta UFC500
영향 받는 버전
- 2.4.18 미만
- 4.4.1 미만
해결 버전
- 2.4.18 이상
- 2.4.18
- 4.4.1 이상