kcve.ai취약점 정보 · 내 자산 확인

CVE-2026-4638 Plaintext Password Disclosure via VBScript Sensor Error Message in Paessler PRTG Network Monitor

설명

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

영향 받는 제품 제품 1개

  • Paessler GmbH

    PRTG Network Monitor

    해결 버전 있음

    영향 받는 버전

    • 26.2.120.1449 미만

    해결 버전

    • 26.2.120.1449 이상

참고 자료 4건

‹ 목록

점검 지원 범위 문의

도입 문의